Document Reference No.: ES_000008
S1-A-7001 RS232 to 1-Port CANbus Adapter User Guide
Version 1.2
Clearance No.: ES #03
©2009-10 EasySync Ltd. 12
4.1.3 Set UART Baud Rate (U)
Summary
Configure RS232 interface with a chosen baud rate. This rate is independent of the CANbus baud
rate. The RS232 baud rate is stored and retained across power cycles.
Upon power-up or reset (R) of the S1-A-7001, the RED LED will flash a given number of times.
NOTE: Ensure the attached RS232 device can be configured for the new baud rate prior to using
this command. Failure to do so may result in an unusable configuration. Many terminal
programs do not have settings beyond 115.2Kbps. The 1.0Mbps setting cannot be used with a
COM port set to 921.6Kbps.
Definition
Urate_selector<CR>
Parameters LED Flash on Power-Up / Reset
rate_selector = 0 = 230.4Kbps 1
1 = 115.2Kbps 2
2 = 57.6Kbps (default) 3
3 = 38.4Kbps 4
4 = 19.2Kbps 5
5 = 9.6Kbps 6
6 = 2.4Kbps 7
7 = 460.8Kbps 8
8 = 1.0Mbps 9
Remarks
Example:
U5<CR>
Set RS232 transmission rate to 9.6Kbps
Return Codes
<CR> = OK
<BELL> = ERROR